14RN60-00M
Revision AV
May 2026
Restrictions: This document contains proprietary information that is protected by copyright; it is intended for use by PCTEL, Inc. and its customers only. It is not to be disclosed to a third party. All rights reserved. No part of this document may be photocopied or reproduced in any way without the prior written permission of PCTEL RF Solutions. The information contained in this document is subject to change without notice. PCTEL RF Solutions makes no warranty of any kind with regard to this document. PCTEL RF Solutions shall not be liable for errors or omissions contained herein or for incidental or consequential damages in connection with the use of this document.
COMMENT ON KNOWN DEFECTS AND OTHER ERRATA
This document lists problems known to be associated with the current release. PCTEL® is committed to releasing defect free products, and appreciates any reports of issues or assistance in the identification of issues. Problems are prioritized and queued for remedy.
PCTEL® is always interested in your feedback concerning our products, and the features or additions that would make them better. Please feel free to contact PCTEL using the support information below with any suggestions for improvements.
Trademarks
© 2026 PCTEL®, Inc. All rights reserved. PCTEL, SeeHawk® Collect, SeeHawk Collect logo, SeeHawk® Touch, SeeHawk Touch logo, SeeHawk® Central, SeeHawk® Monitor, SeeWave®, SeeWave logo, Gflex®, IBflex®, HBflex™, and the PCTEL logo are trademarks of PCTEL, Inc.
Android™ is a trademark of Google Inc.
Bluetooth® is a registered trademark of Bluetooth SIG.
Samsung® and Galaxy Tab® S are registered trademarks of Samsung Electronics, Co. Ltd.
Windows® is a registered trademark of Microsoft Corporation.
Notices and Warranty Information
The information in this document is subject to change without notice. PCTEL assumes no responsibility or makes no warranties for any errors that may appear in this document and disclaims any implied warranty of merchantability or fitness for a particular purpose. Further, PCTEL shall not be liable for incidental, consequential or other damages in connection with the use of this document.
Copyright Information
No part of this document may be used or reproduced in any form or any means, in whole or in part, without prior written consent of PCTEL.
Enterprise Distributed Technologies
Parts of this software Copyright © 2004, Enterprise Distributed Technologies Ltd. All Rights
Reserved.
Parts of this software Copyright © 2002-2003, The KPD-Team. All Rights Reserved.
Parts of this software Copyright © 2002-2003, Routrek Networks. All Rights Reserved.
Parts of this software Copyright © 2002, Chew Keong Tan. All Rights Reserved.
Parts of this software Copyright © 2006, ComponentAce. All Rights Reserved.
Parts of this software Copyright © OpenStreetMap contributors. All Rights Reserved.
Flexera Software LLC
All Rights Reserved
Copyright © 1997-2026 PCTEL®, Inc.
PCTEL
22600 Gateway Center Drive, Suite 100
Clarksburg, MD 20871 USA
Table of Contents
1.0 Current Release Notes........................................................................................ 4
2.0 Previous Release Notes...................................................................................... 6
2.1 Release 6.9.2.0 (December 2025)................................................................ 6
2.2 Release 6.9.0.0 (June 2025).......................................................................... 7
2.3 Release 6.8.0.0 (March 2025)........................................................................ 9
2.4 Release 6.7.0.0 (October 2024)................................................................... 11
2.5 Release 6.6.0.0 (April 2024)......................................................................... 13
2.6 Release 6.5.0.0 (January 2024)................................................................... 15
2.7 Release 6.4.0.0 (October 2023)................................................................... 17
2.8 Release 6.3.0.0 (June 2023)........................................................................ 19
2.9 Release 6.2.0.0 (February 2023)................................................................. 21
2.10 Release 6.1.1.0 (July 2022).......................................................................... 23
2.11 Release 6.1.0.0 (June 2022)........................................................................ 24
2.12 Release 6.0.0.0 (December 2021).............................................................. 27
2.13 Release 5.1.2.0 (August 2021).................................................................... 29
2.14 Release 5.1.1.0 (July 2021).......................................................................... 30
2.15 Release 5.1.0.0 (June 2021)........................................................................ 31
2.16 Release 5.0.1.0 (March 2021)...................................................................... 33
2.17 Release 4.5.2.1 (January 2021)................................................................... 35
2.18 Release 4.5.2.0 (October 2020)................................................................... 36
2.19 Release 4.5.1.2 (September 2020)............................................................. 37
2.20 Release 4.5.0.2 (September 2020)............................................................. 39
2.21 Release 4.4.0.2 (April 2020)......................................................................... 41
2.22 Release 4.4.0.1 (April 2020)......................................................................... 43
1.0 Current Release Notes
COMPONENT VERSION INFORMATION
| Component Name | File Name | Version |
| Main Application (GUI) | SeeHawk.exe | 6.10.0.4 |
| SeeGull Master API | SeeGullMaster.dll | 3.10.0.1 |
| GPS API | DTI_GPS_API.dll | 1.2.0.0 |
FEATURES
- Supports IBflex and HBflex DMR UL Decode scan. Scanner option and firmware 4.1 or later are required.
- Supports IBflex and HBflex Mixed Analog/P25 DL Decode scan and Mixed Analog/P25 UL Decode scan Squelch Type selection with PL, DPL and DPLI values. Scanner firmware 4.1 or later is required.
- Supports Gflex GSM Blind Scan and Color Code scan HRTOA value. Scanner firmware 7.0.4.0 or later is required.
- Supports Base Station Location Estimation feature.
- Supports GSM, WCDMA, LTE, TDLTE and NR technologies.
- Separate Collect feature license is required.
- Supports KML export through Report Generation feature.
- Supports GNS and eGNS files export.
- Supports Uplink data imported using SeeHawk Touch in Analog FM MDC 1200 scan.
SUPPORTED OPERATING SYSTEMS
- Windows 11 Professional Edition, U.S. version only
PHYSICAL SPECIFICATIONS
Recommended Requirements
- PC or laptop with Intel® Core™ i5 or higher processor
- Windows 11 (64bit) Professional Edition (U.S. Version Only)
- 16 GB or higher memory
- 512 GB or larger storage
- USB 2.0, USB 3.0, or USB-C port
KNOWN PROBLEMS & NEW PROBLEMS IDENTIFIED IN THIS RELEASE
None
PROBLEMS RESOLVED IN THIS RELEASE
Defect 8415 Collect may stop responding when using the export wizard.
Collect may stop responding when using the export wizard to export multiple drives repeatedly.
Defect 8578 Collect may stop responding when starting to log data.
Collect may stop responding when users start and stop logging data multiple times in the same session.
2.0 Previous Release Notes
2.1 Release 6.9.2.0 (December 2025)
COMPONENT VERSION INFORMATION
| Component Name | File Name | Version |
| Main Application (GUI) | SeeHawk.exe | 6.9.2.0 |
| SeeGull Master API | SeeGullMaster.dll | 3.9.0.0 |
| GPS API | DTI_GPS_API.dll | 1.2.0.0 |
FEATURES
- No new features. Refer to Problems Resolved in this Release.
Note: SeeHawk Collect 3.8 or earlier must have a license upgrade to use SeeHawk Collect 4.0 and above. Please contact PCTEL Sales for additional information about upgrading license.
SUPPORTED OPERATING SYSTEMS
- Windows 11 Professional Edition, U.S. version only
- Windows 10 Professional Edition (32/64 bit), U.S. version only
PHYSICAL SPECIFICATIONS
Recommended Requirements
- PC or laptop with Intel® Core™ i5 or higher processor
- Windows 11 (64bit) Professional Edition (U.S. Version Only)
- 16 GB or higher memory
- 512 GB or larger storage
- USB 2.0 or USB 3.0 port
KNOWN PROBLEMS & NEW PROBLEMS IDENTIFIED IN THIS RELEASE
Defect 8415 Collect may stop responding when using the export wizard.
Collect may stop responding when using the export wizard to export multiple drives repeatedly.
PROBLEMS RESOLVED IN THIS RELEASE
Defect 8824 Collect may stop responding when opening drive file collected from SeeHawk Touch.
Collect may stop responding when opening drive file collected from SeeHawk Touch that contains LTE scans for playback, export and report generation.
2.2 Release 6.9.0.0 (June 2025)
COMPONENT VERSION INFORMATION
| Component Name | File Name | Version |
| Main Application (GUI) | SeeHawk.exe | 6.9.0.0 |
| SeeGull Master API | SeeGullMaster.dll | 3.9.0.0 |
| GPS API | DTI_GPS_API.dll | 1.2.0.0 |
FEATURES
- Supports IBflex and HBflex DMR OOS-BER scan. Scanner option and firmware 4.0 or later are required.
- Supports IBflex and HBflex DMR OOS-BER Active Scan List scan. Scanner option and firmware 4.0 or later are required.
- Supports IBflex and HBflex P25 UL Traffic Channel Decode, and P25 UL Control Channel Decode symbol deviation and modulation fidelity values. Scanner firmware 4.0 or later is required.
- Supports IBflex and HBflex TETRA Decode and TETRA DL Active Scan List LAC and D-MLE-SYSINFO values. Scanner firmware 4.0 or later is required.
- Supports additional map data modes for TETRA Decode and TETRA DL Active Scan List scan in outdoor maps, indoor maps, and reports.
- Supports RxLev data in GSM Color Code and GSM Blind Scan.
- Supports additional map data modes for GSM Color Code and GSM Blind Scan in outdoor maps, indoor maps, and reports.
- Supports EC data in WCDMA Top N and WCDMA Blind Scan with Layer 3.
- Supports TD Pattern data in NR Top N Signal and NR Blind Scan.
- Supports Time Offset data in milliseconds in LTE, TD-LTE, and NR Blind Scan.
- Supports additional map data modes for GSM, WCDMA, LTE, TD-LTE, and NR Blind Scan.
- Supports NR 5G TDD n77P PCTEL proprietary band.
Note: SeeHawk Collect 3.8 or earlier must have a license upgrade to use SeeHawk Collect 4.0 and above. Please contact PCTEL Sales for additional information about upgrading license.
SUPPORTED OPERATING SYSTEMS
- Windows 11 Professional Edition, U.S. version only
- Windows 10 Professional Edition (32/64 bit), U.S. version only
PHYSICAL SPECIFICATIONS
Recommended Requirements
- PC or laptop with Intel® Core™ i5 or higher processor
- Windows 11 (64bit) Professional Edition (U.S. Version Only)
- 16 GB or higher memory
- 512 GB or larger storage
- USB 2.0 or USB 3.0 port
KNOWN PROBLEMS & NEW PROBLEMS IDENTIFIED IN THIS RELEASE
Defect 8415 Collect may stop responding when using the export wizard.
Collect may stop responding when using the export wizard to export multiple drives repeatedly.
PROBLEMS RESOLVED IN THIS RELEASE
None
2.3 Release 6.8.0.0 (March 2025)
COMPONENT VERSION INFORMATION
| Component Name | File Name | Version |
| Main Application (GUI) | SeeHawk.exe | 6.8.0.0 |
| Drive Tool | PCTEL.DriveTool.dll | 6.8.0.0 |
| SeeGull Master API | SeeGullMaster.dll | 3.8.0.0 |
| GPS API | DTI_GPS_API.dll | 1.2.0.0 |
FEATURES
- Supports IBflex and HBflex Analog FM MDC 1200 scan. Scanner option and firmware 3.14.0.0 or later are required.
- Supports IBflex and HBflex Analog FM frequency offset value. Scanner firmware 3.14.0.0 or later is required.
- Supports Gflex FD-LTE Enhanced Top N Signal scan NTN signal mode and frequency offset value. Scanner firmware 7.0.0.0 or later is required.
- Supports FBER averaging for P25 Decode, P25 DL Active Scan List, DMR Decode, DMR DL Active Scan List, TETRA Decode and TETRA DL Active Scan List in playback, report and export.
- Supports BER averaging for P25 OOS-BER and OOS-BER Active Scan List in playback, report and export.
- Supports additional uplink map data modes for Analog FM scan in outdoor maps, indoor maps, and report.
- Supports RedCap data in NR Top N Signal and NR Blind Scan.
- Supports only autodetect SCS NR Blind Scans and remove all non-autodetect SCS NR Blind Scan for Gflex.
- Update report to include imported uplink frequency.
Note: SeeHawk Collect 3.8 or earlier must have a license upgrade to use SeeHawk Collect 4.0 and above. Please contact PCTEL Sales for additional information about upgrading license.
SUPPORTED OPERATING SYSTEMS
- Windows 11 Professional Edition, U.S. version only
- Windows 10 Professional Edition (32/64 bit), U.S. version only
PHYSICAL SPECIFICATIONS
Recommended Requirements
- PC or laptop with Intel® Core™ i5 or higher processor
- Windows 11 (64bit) Professional Edition (U.S. Version Only)
- 16 GB or higher memory
- 512 GB or larger storage
- USB 2.0 or USB 3.0 port
KNOWN PROBLEMS & NEW PROBLEMS IDENTIFIED IN THIS RELEASE
Defect 8415 Collect may stop responding when using the export wizard.
Collect may stop responding when using the export wizard to export multiple drives repeatedly.
PROBLEMS RESOLVED IN THIS RELEASE
None
2.4 Release 6.7.0.0 (October 2024)
COMPONENT VERSION INFORMATION
| Component Name | File Name | Version |
| Main Application (GUI) | SeeHawk.exe | 6.7.0.0 |
| Drive Tool | PCTEL.DriveTool.dll | 6.7.0.0 |
| SeeGull Master API | SeeGullMaster.dll | 3.7.0.0 |
| GPS API | DTI_GPS_API.dll | 1.2.0.0 |
FEATURES
- Supports IBflex and HBflex Mixed Analog/P25 DL and UL scans. Scanner option and firmware 3.13.0.0 or later are required.
- Supports IBflex and HBflex NR Top N Signal scan on 10 MHz to 6 GHz super band. Scanner option and firmware 3.13.0.0 or later are required.
- Supports IBflex and HBflex FD-LTE Enhanced Top N Signal scan NTN signal mode and frequency offset value. Scanner option and firmware 3.13.0.0 or later are required.
- Supports IBflex and HBflex P25 UL Traffic Decode scan with Phase 2 scrambled signal and frequency offset value. Scanner firmware 3.13.0.0 or later are required.
- Supports Gflex LTE Enhanced Top N Signal scan and Blind Scan Ultra High Speed and 5G/4G Spectrum Sharing UHS modes. Scanner firmware 6.0.0.0 or later is required.
- Supports Gflex LTE Blind Scan One-time MIB/SIBs L3 reporting mode. Scanner firmware 6.0.0.0 or later is required.
- Supports Gflex NB-IoT Blind Scan One-time MIB/SIBs L3 reporting mode. Scanner firmware 6.0.0.0 or later is required.
- Supports Gflex LTE & NB-IoT Blind Scan One-time MIB/SIBs L3 reporting mode. Scanner firmware 6.0.0.0 or later is required.
- Supports Gflex NR Blind Scan One-time MIB/SIBs L3 reporting mode. Scanner firmware 6.0.0.0 or later is required.
- Supports Gflex LTE C-V2X protocol with PC5 Decode scan for beta testing. Scanner option and firmware 6.0.0.0 or later are required.
- Supports drive test list name search, name sorting, and start time sorting.
- New Report features:
- Supports up to 100 drives merging.
- Supports user selectable map plot size.
- Supports NR 5G FDD n31 DL/UL, TDD n54, FDD n72 DL/ UL, FDD n100 DL/UL, and FDD n109 DL/UL bands.
Note: SeeHawk Collect 3.8 or earlier must have a license upgrade to use SeeHawk Collect 4.0 and above. Please contact PCTEL Sales for additional information about upgrading license.
SUPPORTED OPERATING SYSTEMS
- Windows 11 Professional Edition, U.S. version only
- Windows 10 Professional Edition (32/64 bit), U.S. version only
PHYSICAL SPECIFICATIONS
Recommended Requirements
- PC or laptop with Intel® Core™ i5 or higher processor
- Windows 11 (64bit) Professional Edition (U.S. Version Only)
- 16 GB or higher memory
- 512 GB or larger storage
- USB 2.0 or USB 3.0 port
KNOWN PROBLEMS & NEW PROBLEMS IDENTIFIED IN THIS RELEASE
None
PROBLEMS RESOLVED IN THIS RELEASE
Defect 8006 Collect failed to import network configuration file.
Collect failed to import network configuration file.
Defect 8046 Collect may corrupt a test file after being renamed.
Collect may corrupt a test file after being renamed if an invalid character is used in the new name.
Defect 8049 Collect may not load Spectrum Analysis workspace properly.
Collect may not load Spectrum Analysis workspace properly causing the values to change after loading.
Defect 8103 Collect Blind Scan Channel wizard may set up invalid WCDMA Top N Pilot scan.
Collect Blind Scan Channel wizard may set up invalid WCDMA Top N Pilot scan when Layer 3 is part of the selection causing parameter out of range error.
Defect 8158 Collect did not save NR Blind Scan data if it failed to decode the SIB data.
Collect did not save the NR Blind Scan drive data for certain NR bands and channels when it failed to decode the SIB data received for that channel.
Defect 8177 Collect Blind Scan Channel wizard may set up invalid NR Top N scan.
Collect Blind Scan Channel wizard may set up invalid NR Top N scan when Layer 3 is part of the selection causing the option required error.
2.5 Release 6.6.0.0 (April 2024)
COMPONENT VERSION INFORMATION
| Component Name | File Name | Version |
| Main Application (GUI) | SeeHawk.exe | 6.6.0.0 |
| Drive Tool | PCTEL.DriveTool.dll | 6.6.0.0 |
| SeeGull Master API | SeeGullMaster.dll | 3.5.0.0 |
| GPS API | DTI_GPS_API.dll | 1.2.0.0 |
FEATURES
- Supports IBflex and HBflex DMR DL Active Scan List scan.
- Supports IBflex and HBflex TETRA DL Active Scan List scan.
- Supports IBflex and HBflex Analog FM protocol and Analog FM Scan.
- Supports Gflex Wi-Fi Top N scan.
- Supports Gflex Wi-Fi Blind Scan.
- Supports Gflex battery pack information display. Scanner firmware 5.1.0.0 or later is required.
- Supports additional map data modes for NR Top N, P25 RSSI, P25 Decode, DMR RSSI, DMR Decode, TETRA RSSI, TETRA Decode and Custom Channel RSSI scans in outdoor map, indoor map, and report generation.
- New Report features:
- Supports drive name search.
- Supports drive name and drive start time sorting.
- Supports option to filter the report items based on count and KPI.
- Supports saving and loading report document information.
- Supports NR 5G NTN FDD n255 DL/UL, and n256 DL/UL bands.
- Supports FD-LTE EB 106 DL/UL band.
Note: SeeHawk Collect 3.8 or earlier must have a license upgrade to use SeeHawk Collect 4.0 and above. Please contact PCTEL Sales for additional information about upgrading license.
SUPPORTED OPERATING SYSTEMS
- Windows 10 Professional Edition (32/64 bit), U.S. version only
- Windows 11 Professional Edition, U.S. version only
PHYSICAL SPECIFICATIONS
Recommended Requirements
- PC or laptop with Intel Core i5, 2.60 GHz or higher processor
- Windows 10 (64bit) Professional Edition (U.S. Version Only)
- 16 GB RAM or higher
- 512 GB (7200 RPM) or larger hard disk for collecting data
- USB 2.0 ports or later
KNOWN PROBLEMS & NEW PROBLEMS IDENTIFIED IN THIS RELEASE
None
PROBLEMS RESOLVED IN THIS RELEASE
Defect 7611 Collect may stop responding when generating Indoor mode report.
Collect may run out of memory and stop responding when generating Indoor mode report with large indoor map image multiple times.
Defect 7802 Collect may stop responding when generating report.
Collect may stop responding when a corrupted drive is selected to generate report.
2.6 Release 6.5.0.0 (January 2024)
COMPONENT VERSION INFORMATION
| Component Name | File Name | Version |
| Main Application (GUI) | SeeHawk.exe | 6.5.0.0 |
| Drive Tool | PCTEL.DriveTool.dll | 6.5.0.0 |
| SeeGull Master API | SeeGullMaster.dll | 3.4.0.0 |
| GPS API | DTI_GPS_API.dll | 1.2.0.0 |
FEATURES
- Supports IBflex and HBflex NR FR1 Top N Signal scan SIB2 to SIB9. Scanner option and firmware 3.10.0.0 or later are required.
- Supports IBflex and HBflex NR FR1 Blind Scan SIB2 to SIB9. Scanner option and firmware 3.10.0.0 or later are required.
- Supports Gflex NR FR1 Top N Signal scan SIB2 to SIB9. Scanner option and firmware 5.0.0.0 or later are required.
- Supports Gflex NR FR1 Top N Signal polarized antenna scan SIB2 to SIB9. Scanner option and firmware 5.0.0.0 or later are required.
- Supports Gflex NR FR1 Blind Scan SIB2 to SIB9. Scanner option and firmware 5.0.0.0 or later are required.
- Supports Gflex NR FR1 polarized antenna Blind Scan SIB2 to SIB9. Scanner option and firmware 5.0.0.0 or later are required.
- Supports Gflex NR FR2 Top N Signal scan SIB1. Scanner option is required.
- Supports additional SIB1 extracted values for NR FR2 Top N Signal in table view and export.
- Supports additional map data modes for LTE Enhanced Top N Signal, WCDMA Top N Pilot and GSM Control Channel Color Code scans in outdoor map, indoor map, and report generation.
- Supports up to 13 legends in map control.
- New Report features:
- Supports merging multiple drives into single map. A maximum of 20 drives can be merged. All merged drives must be either Outdoor or Indoor drives and must have the same scans. For Indoor mode drives, all drives must be using an indoor map with the same registration.
- Supports multiple of both merged and non-merged drives in single report.
- Supports naming the drives in the report.
- Supports arranging order of the drives in the report.
- Supports generating maps without route.
Note: SeeHawk Collect 3.8 or earlier must have a license upgrade to use SeeHawk Collect 4.0 and above. Please contact PCTEL Sales for additional information about upgrading license.
SUPPORTED OPERATING SYSTEMS
- Windows 10 Professional Edition (32/64 bit), U.S. version only
- Windows 11 Professional Edition, U.S. version only
PHYSICAL SPECIFICATIONS
Recommended Requirements
- PC or laptop with Intel Core i5, 2.60 GHz or higher processor
- Windows 10 (64bit) Professional Edition (U.S. Version Only)
- 16 GB RAM or higher
- 512 GB (7200 RPM) or larger hard disk for collecting data
- USB 2.0 ports or later
KNOWN PROBLEMS & NEW PROBLEMS IDENTIFIED IN THIS RELEASE
Defect 7611 Collect may stop responding when generating Indoor mode report.
Collect may run out of memory and stop responding when generating Indoor mode report with large indoor map image multiple times.
PROBLEMS RESOLVED IN THIS RELEASE
Defect 7526 Collect may throw an unhandled exception during start up.
Collect may throw an unhandled exception error message during application start up if there is no license present.
2.7 Release 6.4.0.0 (October 2023)
COMPONENT VERSION INFORMATION
| Component Name | File Name | Version |
| Main Application (GUI) | SeeHawk.exe | 6.4.0.0 |
| Drive Tool | PCTEL.DriveTool.dll | 6.4.0.0 |
| SeeGull Master API | SeeGullMaster.dll | 3.4.0.0 |
| GPS API | DTI_GPS_API.dll | 1.2.0.0 |
FEATURES
- Supports IBflex and HBflex P25 DL Active Scan List scan.
- Supports IBflex and HBflex P25 OOS-BER Active Scan List scan.
- Supports IBflex and HBflex P25 UL Control Decode frequency offset. Scanner firmware 3.10.0.0 or later is required.
- Supports IBflex and HBflex DMR DL Decode CSysCode and CSBKO values. Scanner option is required.
- Supports setting up Layer 3 in Blind Scan Channel selection wizard.
- Supports additional SIB1 extracted values for NR Top N and NR Blind Scan in table view and export.
- Supports additional map data modes for NB-IoT Blind Scan in outdoor map, indoor map, and report generation.
- Supports NR 5G FR1 n104 and n105 DL/UL bands.
Note: SeeHawk Collect 3.8 or earlier must have a license upgrade to use SeeHawk Collect 4.0 and above. Please contact PCTEL Sales for additional information about upgrading license.
SUPPORTED OPERATING SYSTEMS
- Windows 10 Professional Edition (32/64 bit), U.S. version only
- Windows 11 Professional Edition, U.S. version only
PHYSICAL SPECIFICATIONS
Recommended Requirements
- PC or laptop with Intel Core i5, 2.60 GHz or higher processor
- Windows 10 (64bit) Professional Edition (U.S. Version Only)
- 16 GB RAM or higher
- 512 GB (7200 RPM) or larger hard disk for collecting data
- USB 2.0 ports or later
KNOWN PROBLEMS & NEW PROBLEMS IDENTIFIED IN THIS RELEASE
None
PROBLEMS RESOLVED IN THIS RELEASE
Defect 7413 Outdoor map may fail to download map tiles from Open Street Map.
Outdoor map control may fail to download new map tiles from Open Street Map tile server.
Defect 7422 Blind Scan Channel Wizard may create NR Top N scan with invalid parameter.
Using Blind Scan Channel Wizard after NR Blind Scan with autodetect SCS may create NR Top N scan with invalid parameter.
2.8 Release 6.3.0.0 (June 2023)
COMPONENT VERSION INFORMATION
| Component Name | File Name | Version |
| Main Application (GUI) | SeeHawk.exe | 6.3.0.0 |
| Drive Tool | PCTEL.DriveTool.dll | 6.3.0.0 |
| SeeGull Master API | SeeGullMaster.dll | 3.3.1.0 |
| GPS API | DTI_GPS_API.dll | 1.2.0.0 |
FEATURES
- Supports Gflex LTE & NB-IoT Blind Scan with Mobile Blind Scan and layer 3 decoding. Scanner firmware 4.0.0.0 or later and scanner options are required.
- Supports Gflex NB-IoT Blind Scan with Mobile Blind Scan and layer 3 decoding. Scanner firmware 4.0.0.0 or later and scanner options are required.
- Supports Gflex NB-IoT Top N scan with layer 3 decoding.
- Supports Gflex WCDMA Blind Scan with Mobile Blind Scan and layer 3 decoding. Scanner firmware 4.0.0.0 or later and scanner options are required.
- Supports Uplink data imported using SeeHawk Touch:
- Supports RSSI, P25 Decode, DMR Decode and TETRA Decode scan.
- Supports data display in table view.
- Supports additional map data modes in outdoor map, indoor map, and report generation.
- Supports DTR and CSV export.
- Supports additional map data modes for NR Blind Scan, LTE Blind Scan and Enhanced Top N Signal scan in outdoor map, indoor map, and report generation.
Note: SeeHawk Collect 3.8 or earlier must have a license upgrade to use SeeHawk Collect 4.0 and above. Please contact PCTEL Sales for additional information about upgrading license.
SUPPORTED OPERATING SYSTEMS
- Windows 10 Professional Edition (32/64 bit), U.S. version only
- Windows 11 Professional Edition, U.S. version only
PHYSICAL SPECIFICATIONS
Recommended Requirements
- PC or laptop with Intel Core i5, 2.60 GHz or higher processor
- Windows 10 (64bit) Professional Edition (U.S. Version Only)
- 16 GB RAM or higher
- 512 GB (7200 RPM) or larger hard disk for collecting data
- USB 2.0 ports or later
KNOWN PROBLEMS & NEW PROBLEMS IDENTIFIED IN THIS RELEASE
None
PROBLEMS RESOLVED IN THIS RELEASE
Defect 6999 WCDMA Blind Scan export data is not aligned to header.
WCDMA Blind Scan export data is not aligned to the column header after the EC column.
Defect 7003 Collect may stop responding when exporting Enhanced Top N Signal data.
Collect may stop responding when exporting Enhanced Top N Signal data due to missing sync block.
Defect 7215 NR Blind Scan export missing MCC and MNC information.
NR Blind Scan DTR export missing MCC and MNC information.
2.9 Release 6.2.0.0 (February 2023)
COMPONENT VERSION INFORMATION
| Component Name | File Name | Version |
| Main Application (GUI) | SeeHawk.exe | 6.2.0.0 |
| Drive Tool | PCTEL.DriveTool.dll | 6.2.0.0 |
| SeeGull Master API | SeeGullMaster.dll | 3.3.0.0 |
| GPS API | DTI_GPS_API.dll | 1.2.0.0 |
FEATURES
- Supports Gflex GSM Color Code scan with Layer 3 decoding.
- Supports Gflex GSM Blind Scan with Mobile Blind Scan and Layer 3 decoding. Scanner firmware 3.0.0.0 or later and GSM scanner options are required.
- Supports Gflex NR Blind Scan with Polarized Antenna, MIB decoding, and FR1 SIB1 decoding. Scanner firmware 3.0.0.0 or later and NR scanner options are required.
- Supports Gflex NR Blind Scan iblock selection and Layer 3 reporting mode. Scanner firmware 3.1.1.0 or later is required.
- Supports Gflex FD-LTE and TD-LTE Blind Scan iblock selection and Layer 3 reporting mode. Scanner firmware 3.0.0.0 or later is required.
- Supports Gflex Top N NB-IoT Signal scan.
- Supports IBflex and HBflex NR Blind Scan with Polarized Antenna, MIB decoding, and FR1 SIB1 decoding. Scanner firmware 3.9.0.0 or later, and NR scanner options are required.
- Supports IBflex and HBflex TD-LTE and TD-LTE Blind Scan iblock selection and Layer 3 reporting mode. Scanner firmware 3.9.2.0 or later is required.
- Supports IBflex and HBflex P25 UL Control Channel Decode scan.
- Supports MXflex EPS scan with RF Port selection.
- Supports Cell ID scan for NR Top N Signal scan. Allow user to select one or multiple PCIs to be reported.
- Report features:
- Option to filter the report items based on protocol, channel, frequency, and network name for Top N measurements.
- Option to include or exclude distribution chart to Word report.
- Updated Word report to include scanner type.
Note: SeeHawk Collect 3.8 or earlier must have a license upgrade to use SeeHawk Collect 4.0 and above. Please contact PCTEL Sales for additional information about upgrading license.
SUPPORTED OPERATING SYSTEMS
- Windows 10 Professional Edition (32/64 bit), U.S. version only
- Windows 11 Professional Edition, U.S. version only
PHYSICAL SPECIFICATIONS
Recommended Requirements
- PC or laptop with Intel Core i5, 2.60 GHz or higher processor
- Windows 10 (64bit) Professional Edition (U.S. Version Only)
- 16 GB RAM or higher
- 512 GB (7200 RPM) or larger hard disk for collecting data
- USB 2.0 ports or later
KNOWN PROBLEMS & NEW PROBLEMS IDENTIFIED IN THIS RELEASE
None
PROBLEMS RESOLVED IN THIS RELEASE
Defect 6548 NR Top N Data Viewer stop responding.
Nr Top N Data Viewer for MIB and SIB may stop responding.
Defect 6560 NR Blind Scan report display incorrect measurement mode.
NR Blind Scan report displays incorrect measurement mode.
Defect 6565 Collect report incorrect scanner fail to respond if 16 channels of P25 UL Decode scan is setup.
Collect report incorrect scanner fail to response message if 16 channels of P25 UL Decode scan is setup.
Defect 6900 Missing network name in NR Blind Scan summary.
Missing network name in NR Blind Scan summary.
Defect 6924 Fail to setup NB-IoT Top N Signal frequency value.
Fail to setup NB-IoT Top N Signal frequency value under wideband.
Defect 6932 Collect report fails to generate certain map when using test data with multiple scanners.
Collect report fail to generate certain map when using test data with multiple scanners.
Defect 6935 Collect report fails to include network name for Nr Blind Scan.
Collect report fails to include network name for Nr Blind Scan.
Defect 6965 Blind Scan wizard displays multiple error messages.
Blind Scan wizard displays multiple error messages blocking other UI interaction.
2.10 Release 6.1.1.0 (July 2022)
COMPONENT VERSION INFORMATION
| Component Name | File Name | Version |
| Main Application (GUI) | SeeHawk.exe | 6.1.1.0 |
| Drive Tool | PCTEL.DriveTool.dll | 6.1.1.0 |
| SeeGull Master API | SeeGullMaster.dll | 3.2.0.0 |
| GPS API | DTI_GPS_API.dll | 1.2.0.0 |
FEATURES
- No new features. Refer to Problems Resolved in this Release.
Note: SeeHawk Collect 3.8 or earlier must have a license upgrade to use SeeHawk Collect 4.0 and above. Please contact PCTEL Sales for additional information about upgrading license.
SUPPORTED OPERATING SYSTEMS
- Windows 10 Professional Edition (32/64 bit), U.S. version only
- Windows 11 Professional Edition, U.S. version only
PHYSICAL SPECIFICATIONS
Recommended Requirements
- PC or laptop with Intel Core i5, 2.60 GHz or higher processor
- Windows 10 (64bit) Professional Edition (U.S. Version Only)
- 16 GB RAM or higher
- 512 GB (7200 RPM) or larger hard disk for collecting data
- USB 2.0 ports
KNOWN PROBLEMS & NEW PROBLEMS IDENTIFIED IN THIS RELEASE
None
PROBLEMS RESOLVED IN THIS RELEASE
Defect 6544 Collect fails to run Blind Scan on IBflex scanners that do not have Mobile Blind Scan option enabled.
Collect fails to run Blind Scan on IBflex scanners that do not have the Mobile Blind Scan option enabled for that technology and gives “option required” error message.
2.11 Release 6.1.0.0 (June 2022)
COMPONENT VERSION INFORMATION
| Component Name | File Name | Version |
| Main Application (GUI) | SeeHawk.exe | 6.1.0.0 |
| Drive Tool | PCTEL.DriveTool.dll | 6.1.0.0 |
| SeeGull Master API | SeeGullMaster.dll | 3.2.0.0 |
| GPS API | DTI_GPS_API.dll | 1.2.0.0 |
FEATURES
- Supports Gflex GSM Color Code scan.
- Supports Gflex LTE Enhanced Top N Signal Layer 3 decoding.
- Supports Gflex LTE Blind Scan with 5G / 4G Spectrum Sharing mode.
- Supports Gflex nr Top N Signal MIB decoding and Polarized Antenna mode.
- Supports Gflex nr Blind Scan MIB decoding. Scanner firmware 1.5.0.0 or later, and nr MIB scanner options are required.
- Supports Gflex nr Blind Scan Cell Defining SSB measurement mode. Scanner firmware 1.5.0.0 or later is required.
- Supports IBflex and HBflex nr Blind Scan MIB decoding. Scanner firmware 3.8.7.0 or later, and nr MIB scanner options are required.
- Supports IBflex and HBflex nr Blind Scan Polarized Antenna and Cell Defining SSB measurement mode. Scanner firmware 3.8.6.0 or later, and Polarized Antenna scanner options are required.
- Supports antenna gain and cable loss in Blind Scan.
- Supports additional map data modes for nr Blind Scan, and LTE Blind Scan in outdoor map, indoor map, and report generation.
- Report features:
- Supports high resolution image. Image resolution is scaled down below 4000 x 4000.
- Supports custom logo for report generation.
- Updated Word report to include Date Tested in summary.
- Supports multiple channels, frequencies, pilot, or PCI report items setup.
- Supports NR 5G FR1 n77 Lower proprietary, n77 Upper proprietary, n101, and n102 bands.
- Supports FD-LTE EB 103 DL/UL band.
- Supports Public Safety 10 – 1000 MHz wide band for P25.
Note: SeeHawk Collect 3.8 or earlier must have a license upgrade to use SeeHawk Collect 4.0 and above. Please contact PCTEL Sales for additional information about upgrading license.
SUPPORTED OPERATING SYSTEMS
- Windows 10 Professional Edition (32/64 bit), U.S. version only
- Windows 11 Professional Edition, U.S. version only
PHYSICAL SPECIFICATIONS
Recommended Requirements
- PC or laptop with Intel Core i5, 2.60 GHz or higher processor
- Windows 10 (64bit) Professional Edition (U.S. Version Only)
- 16 GB RAM or higher
- 512 GB (7200 RPM) or larger hard disk for collecting data
- USB 2.0 ports
KNOWN PROBLEMS & NEW PROBLEMS IDENTIFIED IN THIS RELEASE
None
PROBLEMS RESOLVED IN THIS RELEASE
Defect 6360 Collect stop responding when trying to generate report.
Collect stop responding when trying to generate report due to running out of memory.
Defect 6375 Collect stop responding when trying to generate report.
Collect stop responding when trying to generate report due to large floor plan images.
Defect 6390 Collect missing restriction on Gflex custom channel.
Collect missing restriction on setting up custom channel for Gflex result in rejection from the scanner. Gflex custom channel RBW must be equal to FSS.
Defect 6409 Collect missing restriction on Gflex custom channel for mmWave.
Collect missing restriction on setting up custom channel for Gflex result in rejection from the scanner. Gflex mmWave custom channel RBW must be equal to FSS.
Defect 6416 Collect missing restriction on Gflex custom channel for mmWave.
Collect missing restriction on setting up custom channel for Gflex result in rejection from the scanner. Gflex mmWave custom channel RBW must be at least 10kHz and multiple of 5kHz.
Defect 6436 Collect fails to playback and generate report.
Collect fails to playback and generate report for indoor test with large floor plan image.
Defect 6466 Missing Reference Signal Guard Period Power in Enhanced Top N Signal export.
Missing Reference Signal Guard Period Power in Enhanced Top N Signal export for Gflex scanning receiver.
Defect 6485 Collect fails to read data file greater than 2GB.
Collect fails to read data file greater than 2GB. Test playback and export stops after reaching the 2GB limit.
Defect 6529 Custom Channel RSSI time sampling failed to load from workspace.
Custom Channel RSSI time sampling setting fail to load from workspace properly.
2.12 Release 6.0.0.0 (December 2021)
COMPONENT VERSION INFORMATION
| Component Name | File Name | Version |
| Main Application (GUI) | SeeHawk.exe | 6.0.0.0 |
| Drive Tool | PCTEL.DriveTool.dll | 6.0.0.0 |
| SeeGull Master API | SeeGullMaster.dll | 3.1.0.1 |
| GPS API | DTI_GPS_API.dll | 1.2.0.0 |
FEATURES
- Supports Gflex scanning receiver through USB connection.
- Supports NR 5G FR1 n13DL/UL, n24DL/UL, n26DL/UL, n46, n47, n67DL, n85DL/UL, n96, n97, n98 and n99 bands.
- Supports NR 5G FR2 n259 and n262 bands.
- Supports high resolution image in report generation.
Note: SeeHawk Collect Indoor Maps can throw an ‘Unhandled exception. Out of Memory’ error if the image size is greater than 4000x4000 and has multiple Indoor maps. This can happen during data collection, playback and Report generation.
Note: SeeHawk Collect Reports can throw an ‘Unhandled exception. Out of Memory’ error if there are multiple drives with huge amount of data. This can happen mostly with Outdoor drives that has huge amount of data or if multiple scanners with multiple measurements are used.
Note: SeeHawk Collect 3.8 or earlier must have a license upgrade to use SeeHawk Collect 4.0 and above. Please contact PCTEL Sales for additional information about upgrading license.
SUPPORTED OPERATING SYSTEMS
- Windows 10 Professional Edition (32/64 bit), U.S. version only
PHYSICAL SPECIFICATIONS
Recommended Requirements
- PC or laptop with Intel Core i5, 2.60 GHz or higher processor
- Windows 10 (64bit) Professional Edition (U.S. Version Only)
- 16 GB RAM or higher
- 512 GB (7200 RPM) or larger hard disk for collecting data
- USB 2.0 ports
KNOWN PROBLEMS & NEW PROBLEMS IDENTIFIED IN THIS RELEASE
None
PROBLEMS RESOLVED IN THIS RELEASE
Defect 5877 Collect fails to display Wi-Fi Top N summary.
Collect fails to display Wi-Fi Top N summary in drive summary dialog.
Defect 5878 Collect may fail to export drive data.
Collect may fail to export drive data when going back from Start Export page and then going forward in the Export Wizard.
Defect 6241 Collect may fail to open large drive data.
Collect may fail to open large drive data (more than 10Gb) for playback or export.
Defect 6284 Blind Scan Channel Selection Wizard may not work properly for nr.
Blind Scan Channel Selection Wizard may use the wrong number of RF port to setup nr Top N scan causing scan fail to start.
Defect 6308 Generated report may contain incorrect data.
Generated report may contain incorrect data when there are multiple channels for the same band. This apply to Top N Pilot, Enhanced Top N Signal, Quick Top N, Top N NB-IoT and nr Top N Signal scans
2.13 Release 5.1.2.0 (August 2021)
COMPONENT VERSION INFORMATION
| Component Name | File Name | Version |
| Main Application (GUI) | SeeHawk.exe | 5.1.2.0 |
| Drive Tool | PCTEL.DriveTool.dll | 5.1.2.0 |
| SeeGull Master API | SeeGullMaster.dll | 3.0.0.0 |
| GPS API | DTI_GPS_API.dll | 1.2.0.0 |
FEATURES
- No new features. Refer to Problems Resolved in this Release.
Note: SeeHawk Collect 3.8 or earlier must have a license upgrade to use SeeHawk Collect 4.0 and above. Please contact PCTEL Sales for additional information about upgrading license.
SUPPORTED OPERATING SYSTEMS
- Windows 10 Professional Edition (32/64 bit), U.S. version only
PHYSICAL SPECIFICATIONS
Recommended Requirements
- PC or laptop with Intel Core i5, 2.60 GHz or higher processor
- Windows 10 (64bit) Professional Edition (U.S. Version Only)
- 16 GB RAM or higher
- 512 GB (7200 RPM) or larger hard disk for collecting data
- USB 2.0 ports
KNOWN PROBLEMS & NEW PROBLEMS IDENTIFIED IN THIS RELEASE
None
PROBLEMS RESOLVED IN THIS RELEASE
Defect 6185 Unable to edit and save generated report.
User may be unable to edit and save Word report generated by SeeHawk Collect in certain versions of Microsoft Word. Image in the document may seem to be corrupted.
2.14 Release 5.1.1.0 (July 2021)
COMPONENT VERSION INFORMATION
| Component Name | File Name | Version |
| Main Application (GUI) | SeeHawk.exe | 5.1.1.0 |
| Drive Tool | PCTEL.DriveTool.dll | 5.1.1.0 |
| SeeGull Master API | SeeGullMaster.dll | 3.0.0.0 |
| GPS API | DTI_GPS_API.dll | 1.2.0.0 |
FEATURES
- No new features. Refer to Problems Resolved in this Release.
Note: SeeHawk Collect 3.8 or earlier must have a license upgrade to use SeeHawk Collect 4.0 and above. Please contact PCTEL Sales for additional information about upgrading license.
SUPPORTED OPERATING SYSTEMS
- Windows 10 Professional Edition (32/64 bit), U.S. version only
PHYSICAL SPECIFICATIONS
Recommended Requirements
- PC or laptop with Intel Core i5, 2.60 GHz or higher processor
- Windows 10 (64bit) Professional Edition (U.S. Version Only)
- 16 GB RAM or higher
- 512 GB (7200 RPM) or larger hard disk for collecting data
- USB 2.0 ports
KNOWN PROBLEMS & NEW PROBLEMS IDENTIFIED IN THIS RELEASE
None
PROBLEMS RESOLVED IN THIS RELEASE
Defect 6110 Fail to connect to default cloud licensing server.
SeeHawk Collect fails to connect to default cloud licensing server.
Defect 6111 Fail to display data in nr Top N Signal table and export nr Top N Signal data.
SeeHawk Collect fails to display data in nr Top N Signal table and export nr Top N Signal data when SIB1 detection is enabled and multiple MCC-MNC blocks are detected.
2.15 Release 5.1.0.0 (June 2021)
COMPONENT VERSION INFORMATION
| Component Name | File Name | Version |
| Main Application (GUI) | SeeHawk.exe | 5.1.0.0 |
| Drive Tool | PCTEL.DriveTool.dll | 5.1.0.0 |
| SeeGull Master API | SeeGullMaster.dll | 3.0.0.0 |
| GPS API | DTI_GPS_API.dll | 1.2.0.0 |
FEATURES
- Supports new cloud-based licensing.
- License can be acquired for a 24-hour period and automatically expired and returned after expiring.
- Require customer to have cloud-based license.
- Supports multiple NR Blind Scans for each band in different sub carrier spacing.
Note: SeeHawk Collect 3.8 or earlier must have a license upgrade to use SeeHawk Collect 4.0 and above. Please contact PCTEL Sales for additional information about upgrading license.
SUPPORTED OPERATING SYSTEMS
- Windows 10 Professional Edition (32/64 bit), U.S. version only
PHYSICAL SPECIFICATIONS
Recommended Requirements
- PC or laptop with Intel Core i5, 2.60 GHz or higher processor
- Windows 10 (64bit) Professional Edition (U.S. Version Only)
- 16 GB RAM or higher
- 512 GB (7200 RPM) or larger hard disk for collecting data
- USB 2.0 ports
KNOWN PROBLEMS & NEW PROBLEMS IDENTIFIED IN THIS RELEASE
None
PROBLEMS RESOLVED IN THIS RELEASE
Defect 5879 Fail to detect network devices after auto update.
SeeHawk Collect may fail to detect network devices after user selects application auto update.
Defect 5885 TETRA fixed bands RSSI missing in report.
TETRA fixed bands RSSI measurements are missing in report.
Defect 5886 Incorrect detected NR frequencies displayed in Blind Scan Report.
Incorrect detected NR frequencies from other scanners are displayed in Blind Scan Report control. This only affected when multiple scanners are used to run Blind Scan.
Defect 5887 Display duplicate cell ID selection for NR Blind Scan Map setup.
Display duplicate cell IDs in the selection list for NR Blind Scan Map setup.
Defect 5936 Export incorrect latitude and longitude to DTR and CSV for Indoor test.
Collect exports incorrect latitude and longitude values to DTR and CSV files for Indoor test.
Defect 5979 CSV export column headers for NR Blind Scan may be shifted.
Column headers for CSV file exported for NR Blind Scan may be shifted when SSB RSSI 2 value is included.
2.16 Release 5.0.1.0 (March 2021)
COMPONENT VERSION INFORMATION
| Component Name | File Name | Version |
| Main Application (GUI) | SeeHawk.exe | 5.0.1.0 |
| Drive Tool | PCTEL.DriveTool.dll | 5.0.1.0 |
| SeeGull Master API | SeeGullMaster.dll | 2.9.0.0 |
| GPS API | DTI_GPS_API.dll | 1.2.0.0 |
FEATURES
- Supports SeeGull IBflex and HBflex polarized antenna mode in nr Top N Signal.
- Supports SeeGull IBflex and HBflex 5G / 4G Spectrum Sharing mode in LTE Blind Scan.
- New Blind Scan Band View control.
- New Interfering MCC-MNC detection features:
- Supports known MCC-MNC whitelist setup.
- Supports Interfering MCC-MNC Data control.
- Supports data display in map.
- Supports data export.
- Supports additional map data modes for P25 Decode, TETRA Decode, DMR Decode, and Top N Wi-Fi scans in outdoor map, indoor map, and report generation.
- Supports Network Configuration File for nr 5G.
- Supports SeeHawk Collect Application auto update based on maintenance license.
Note: SeeHawk Collect 3.8 or earlier must have a license upgrade to use SeeHawk Collect 4.0 and above. Please contact PCTEL Sales for additional information about upgrading license.
SUPPORTED OPERATING SYSTEMS
- Windows 10 Professional Edition (32/64 bit), U.S. version only
PHYSICAL SPECIFICATIONS
Recommended Requirements
- PC or laptop with Intel Core i5, 2.60 GHz or higher processor
- Windows 10 (64bit) Professional Edition (U.S. Version Only)
- 16 GB RAM or higher
- 512 GB (7200 RPM) or larger hard disk for collecting data
- USB 2.0 ports
KNOWN PROBLEMS & NEW PROBLEMS IDENTIFIED IN THIS RELEASE
None
PROBLEMS RESOLVED IN THIS RELEASE
Defect 5742 Column headers misalign in Enhanced Top N Signal export.
Column headers in Enhanced Top N Signal DTR and CSV export could be misaligned when MIMO feature is enabled.
Defect 5743 Column headers missing in Enhanced Top N Signal export.
Few column headers in Enhanced Top N Signal CSV export could be missing when channel matrix feature is enabled.
Defect 5760 Unable to include GSM map into report.
Unable to include GSM Greatest RSSI and Greatest C/I map into report.
Defect 5767 NR Top N Signal table not displaying all beams.
NR Top N Signal table not displaying data for all detected beams.
Defect 5778 Exported CSV file may contain E notation values.
Exported CSV file may contain E notation in latitude and longitude values.
Defect 5852 Wi-Fi Top N table and bar chart fail to show all data.
Wi-Fi Top N table and bar chart fail to show all detected SSIDs when there are SSIDs with different MAC addresses.
Defect 5873 Wi-Fi Blind Scan report contains incorrect channels.
Wi-Fi Blind Scan report contains incorrect detected channels number.
2.17 Release 4.5.2.1 (January 2021)
COMPONENT VERSION INFORMATION
| Component Name | File Name | Version |
| Main Application (GUI) | SeeHawk.exe | 4.5.2.1 |
| Drive Tool | PCTEL.DriveTool.dll | 4.5.2.1 |
| SeeGull Master API | SeeGullMaster.dll | 2.7.0.1 |
| GPS API | DTI_GPS_API.dll | 1.2.0.0 |
FEATURES
- No new features. Refer to Problems Resolved in this Release.
Note: SeeHawk Collect 3.8 or earlier must have a license upgrade to use SeeHawk Collect 4.0 and above. Please contact PCTEL Sales for additional information about upgrading license.
SUPPORTED OPERATING SYSTEMS
- Windows 10 Professional Edition (32/64 bit), U.S. version only
PHYSICAL SPECIFICATIONS
Recommended Requirements
- PC or laptop with Intel Core i5, 2.60 GHz or higher processor
- Windows 10 (64bit) Professional Edition (U.S. Version Only)
- 8 GB RAM or higher
- 512 GB (7200 RPM) or larger hard disk for collecting data
- USB 2.0 ports
KNOWN PROBLEMS & NEW PROBLEMS IDENTIFIED IN THIS RELEASE
None
PROBLEMS RESOLVED IN THIS RELEASE
Defect 5797 SeeHawk Collect incorrect limit on nr Top N Signal scan channels.
SeeHawk Collect incorrectly limit the number of channels for nr Top N Signal scan when using Mxflex with firmware 5.7.1.0, which allow 24 FR1 channels
2.18 Release 4.5.2.0 (October 2020)
COMPONENT VERSION INFORMATION
| Component Name | File Name | Version |
| Main Application (GUI) | SeeHawk.exe | 4.5.2.0 |
| Drive Tool | PCTEL.DriveTool.dll | 4.5.2.0 |
| SeeGull Master API | SeeGullMaster.dll | 2.7.0.1 |
| GPS API | DTI_GPS_API.dll | 1.2.0.0 |
FEATURES
- Supports SeeGull IBflex and HBflex nr Top N Signal scan SIB1 decoding.
Note: SeeHawk Collect 3.8 or earlier must have a license upgrade to use SeeHawk Collect 4.0 and above. Please contact PCTEL Sales for additional information about upgrading license.
SUPPORTED OPERATING SYSTEMS
- Windows 10 Professional Edition (32/64 bit), U.S. version only
PHYSICAL SPECIFICATIONS
Recommended Requirements
- PC or laptop with Intel Core i5, 2.60 GHz or higher processor
- Windows 10 (64bit) Professional Edition (U.S. Version Only)
- 8 GB RAM or higher
- 512 GB (7200 RPM) or larger hard disk for collecting data
- USB 2.0 ports
KNOWN PROBLEMS & NEW PROBLEMS IDENTIFIED IN THIS RELEASE
None
PROBLEMS RESOLVED IN THIS RELEASE
Defect 5669 Missing data in NB-IoT export.
Top N NB-IoT export is missing adjusted NRS RP value.
Defect 5683 eMBMS Antenna gain and cable loss values overwrites header on table.
Changing Antenna gain and cable loss values with the table open it overwrites the table header displaying the antenna gain and cable loss values.
2.19 Release 4.5.1.2 (September 2020)
COMPONENT VERSION INFORMATION
| Component Name | File Name | Version |
| Main Application (GUI) | SeeHawk.exe | 4.5.1.2 |
| Drive Tool | PCTEL.DriveTool.dll | 4.5.1.2 |
| SeeGull Master API | SeeGullMaster.dll | 2.7.0.1 |
| GPS API | DTI_GPS_API.dll | 1.2.0.0 |
FEATURES
- No new features. Refer to Problems Resolved in this Release.
Note: SeeHawk Collect 3.8 or earlier must have a license upgrade to use SeeHawk Collect 4.0 and above. Please contact PCTEL Sales for additional information about upgrading license.
SUPPORTED OPERATING SYSTEMS
- Windows 10 Professional Edition (32/64 bit), U.S. version only
PHYSICAL SPECIFICATIONS
Recommended Requirements
- PC or laptop with Intel Core i5, 2.60 GHz or higher processor
- Windows 10 (64bit) Professional Edition (U.S. Version Only)
- 8 GB RAM or higher
- 512 GB (7200 RPM) or larger hard disk for collecting data
- USB 2.0 ports
KNOWN PROBLEMS & NEW PROBLEMS IDENTIFIED IN THIS RELEASE
Defect 5669 Missing data in NB-IoT export.
Top N NB-IoT export is missing adjusted NRS RP value.
Defect 5683 eMBMS Antenna gain and cable loss values overwrites header on table.
Changing Antenna gain and cable loss values with the table open it overwrites the table header displaying the antenna gain and cable loss values.
PROBLEMS RESOLVED IN THIS RELEASE
Defect 5661 Bar Chart fail to reflect antenna gain and cable lost change.
Bar Chart for eMBMS fail to reflect the change for antenna gain and cable loss values until the control is closed and reopen.
Defect 5662 SeeHawk Collect may not responding when changing antenna gain and cable lost values for eMBMS.
SeeHawk Collect application may not be responding for few seconds when changing antenna gain and cable lost values for eMBMS measurement.
Defect 5680 SeeHawk Collect crashes.
SeeHawk Collect crashes when try to generate report from Indoor test that contains map registration using UTM coordinate system.
2.20 Release 4.5.0.2 (September 2020)
COMPONENT VERSION INFORMATION
| Component Name | File Name | Version |
| Main Application (GUI) | SeeHawk.exe | 4.5.0.2 |
| Drive Tool | PCTEL.DriveTool.dll | 4.5.0.2 |
| SeeGull Master API | SeeGullMaster.dll | 2.6.0.0 |
| GPS API | DTI_GPS_API.dll | 1.2.0.0 |
FEATURES
- New test report with following features:
- A licensed feature to generate report from drive or walk test.
- Supports report template creation for reuse.
- Supports multiple drives in single report.
- Supports multiple map data (limit to 250) and distribution charts in single report.
- Supports export of report image data to image files.
- Supports export report data to Microsoft Word document.
- Replaced Indoor Map Control with following features:
- Supports RSSI scan, Enhanced Power scan, Spectrum Analyzer scan, Color Code scan, Top N Pilot scan, Enhanced Top N Signal scan, Top N eMBMS scan, Top N NB-IoT scan, Quick Top N Signal scan, Power Analysis Slots Guard Period scan, Top N Wi-Fi scan, Wi-Fi throughput scan, nr Top N Signal scan, P25 Decode scan, DMR Decode scan, TETRA Decode scan and Blind Scan.
- Supports editable legend range.
- Supports SeeGull HBflex 1 RF port selection for 40ms SSB periodicity in nr Top N Signal scan for FR2 bands.
- Supports SeeGull MXflex 5G / 4G Spectrum Sharing mode in Enhanced Top N Signal scan.
- Supports LTE-M data in Enhanced Top N Signal scan and LTE Blind scan.
- Supports NR 5G FR1 TDD n53 and FR1 SUL n89 bands.
- Supports FD-LTE EB 87 DL/UL and EB 88 DL/UL bands.
- Supports TD-LTE EB 53 band.
Note: SeeHawk Collect 3.8 or earlier must have a license upgrade to use SeeHawk Collect 4.0 and above. Please contact PCTEL Sales for additional information about upgrading license.
SUPPORTED OPERATING SYSTEMS
- Windows 10 Professional Edition (32/64 bit), U.S. version only
PHYSICAL SPECIFICATIONS
Recommended Requirements
- PC or laptop with Intel Core i5, 2.60 GHz or higher processor
- Windows 10 (64bit) Professional Edition (U.S. Version Only)
- 8 GB RAM or higher
- 512 GB (7200 RPM) or larger hard disk for collecting data
- USB 2.0 ports
KNOWN PROBLEMS & NEW PROBLEMS IDENTIFIED IN THIS RELEASE
Defect 5661 Bar Chart fail to reflect antenna gain and cable lost change.
Bar Chart for eMBMS fail to reflect the change for antenna gain and cable lost values until the control is closed and reopen.
Defect 5662 SeeHawk Collect may not responding when changing antenna gain and cable lost values for eMBMS.
SeeHawk Collect application may not be responding for few seconds when changing antenna gain and cable lost values for eMBMS measurement.
Defect 5669 Missing data in NB-IoT export.
Top N NB-IoT export is missing adjusted NRS RP value.
PROBLEMS RESOLVED IN THIS RELEASE
Defect 5506 Fail to validate scanner options when loading workspace.
SeeHawk Collect fails to validate connected scanner options when loading ESN specific workspace. If scanners’ options in the workspace is different from the connected scanners’ options, the options from the workspace will be used.
Defect 5560 Missing data in NB-IoT export.
Top N NB-IoT export is missing antenna gain and cable loss values.
Defect 5647 SeeHawk Collect not responding in Indoor Mode.
SeeHawk Collect not responding when running RSSI scan in Indoor Mode.
2.21 Release 4.4.0.2 (April 2020)
COMPONENT VERSION INFORMATION
| Component Name | File Name | Version |
| Main Application (GUI) | SeeHawk.exe | 4.4.0.2 |
| Drive Tool | PCTEL.DriveTool.dll | 4.4.0.2 |
| SeeGull Master API | SeeGullMaster.dll | 2.5.0.0 |
| GPS API | DTI_GPS_API.dll | 1.2.0.0 |
FEATURES
- No new features. Refer to Problems Resolved in this Release.
Note: SeeHawk Collect 3.8 or earlier must have a license upgrade to use SeeHawk Collect 4.0 and above. Please contact PCTEL Sales for additional information about upgrading license.
SUPPORTED OPERATING SYSTEMS
- Windows 10 Professional Edition (32/64 bit), U.S. version only
- Windows 8 Professional Edition (32/64 bit), U.S. version only
- Windows 7 Professional Edition (32/64 bit), U.S. version only
PHYSICAL SPECIFICATIONS
Recommended Requirements
- PC or laptop with Intel Core i5, 2.60 GHz or higher processor
- Windows 10 (64bit) Professional Edition (U.S. Version Only)
- 8 GB RAM or higher
- 512 GB (7200 RPM) or larger hard disk for collecting data
- USB 2.0 ports
KNOWN PROBLEMS & NEW PROBLEMS IDENTIFIED IN THIS RELEASE
Defect 5506 Fail to validate scanner options when loading workspace.
SeeHawk Collect fails to validate connected scanner options when loading ESN specific workspace. If scanners’ options in the workspace is different from the connected scanners’ options, the options from the workspace will be used.
The workaround for this is loading the workspace as General (Load Workspace-General) instead of ESN specific to see all scanner options on Collect.
PROBLEMS RESOLVED IN THIS RELEASE
Defect 5505 Fail to start scan.
SeeHawk Collect fails to start scan when scanner does not contain NR protocol.
2.22 Release 4.4.0.1 (April 2020)
COMPONENT VERSION INFORMATION
| Component Name | File Name | Version |
| Main Application (GUI) | SeeHawk.exe | 4.4.0.1 |
| Drive Tool | PCTEL.DriveTool.dll | 4.4.0.1 |
| SeeGull Master API | SeeGullMaster.dll | 2.5.0.0 |
| GPS API | DTI_GPS_API.dll | 1.2.0.0 |
FEATURES
- Supports new DMR (Digital Mobile Radio) protocol.
- Supports SeeGull IBflex and HBflex DMR Decode scan with Color Code.
- Supports SeeGull IBflex and HBflex TETRA Decode scan with Color Code, MCC and MNC.
- Supports SeeGull IBflex and HBflex NB-IoT Blind Scan.
- Supports SeeGull IBflex and HBflex SSB repetition period flag and single RF port scan in nr Top N Signal scan.
- Supports SeeGull IBflex and HBflex 5G / 4G Spectrum Sharing mode in Enhanced Top N Signal scan.
- Supports SeeGull IBflex DC power level display during data collection.
- Supports P25 Decode scan line chart.
- Supports Enhanced Top N Signal multiple channels line chart.
- Supports Non-Uniform Custom Channel RSSI scan line chart.
- Replaced Outdoor Map Control with following features:
- Supports Open Street Map tiles download.
- Supports RSSI scan, Enhanced Power scan, Spectrum Analyzer scan, Color Code scan, Top N Pilot scan, Enhanced Top N Signal scan, Top N eMBMS scan, Top N NB-IoT scan, Quick Top N Signal scan, Power Analysis Slots Guard Period scan, Top N Wi-Fi scan, Wi-Fi throughput scan, nr Top N Signal scan, P25 Decode scan, DMR Decode scan, TETRA Decode scan and Blind Scan.
- Supports editable legend range.
- Supports event layer display.
- Supports NCF layer display.
- Supports DMR / TETRA 10 – 1000 MHz and 570 – 1000 MHz wide bands.
- Supports NR 5G FR1 FDD n14 DL, FR1 FDD n14 UL, FR1 FDD n18 DL, FR1 FDD n18 UL, FR1 SDL n29, FR1 FDD n30 DL, FR1 FDD n30 UL, FR1 TDD n48, FR1 TDD n90, FR1 FDD n91 DL, FR1 FDD n91 UL, FR1 FDD n92 DL, FR1 FDD n92 UL, FR1 FDD n93 DL, FR1 FDD n93 UL, FR1 FDD n94 DL, FR1 FDD n94 UL and FR1 SUL n95 bands.
Note: SeeHawk Collect 3.8 or earlier must have a license upgrade to use SeeHawk Collect 4.0 and above. Please contact PCTEL Sales for additional information about upgrading license.
SUPPORTED OPERATING SYSTEMS
- Windows 10 Professional Edition (32/64 bit), U.S. version only
- Windows 8 Professional Edition (32/64 bit), U.S. version only
- Windows 7 Professional Edition (32/64 bit), U.S. version only
PHYSICAL SPECIFICATIONS
Recommended Requirements
- PC or laptop with Intel Core i5, 2.60 GHz or higher processor
- Windows 10 (64bit) Professional Edition (U.S. Version Only)
- 8 GB RAM or higher
- 512 GB (7200 RPM) or larger hard disk for collecting data
- USB 2.0 ports
External Device Requirements
- Appropriately programmed software key for all options
KNOWN PROBLEMS & NEW PROBLEMS IDENTIFIED IN THIS RELEASE
None
PROBLEMS RESOLVED IN THIS RELEASE
Defect 5315 Not able to select few frequencies for nr TopN Signal scan.
SeeHawk Collect may display error when user select certain frequencies to be added for nr TopN Signal scan.
Defect 5318 Incorrect GSM Color Code RSSI threshold range.
SeeHawk Collect limits the GSM Color Code RSSI threshold range from -115 to -80. Correct range based on scanner should be -120 to -20.
Defect 5320 Fail to load workspace for P25 Decode scan.
SeeHawk Collect fails to load workspace containing P25 Decode scan when scanner does not have EPS option, which is not required for the P25 Decode scan.
Defect 5397 Fail to create summary file.
SeeHawk Collect fails to create summary file for a test when user pause the test and then stop the test.
Defect 5406 Fail to release transferable license.
SeeHawk Collect fails to release the transferable license completely from the host PC.
Defect 5448 Fail to restore all Spectrum Analysis scans.
SeeHawk Collect fails to restore all Spectrum Analysis scans that belong to a single band from workspace file.